Copeland compressor model number nomenclature
Copeland compressor model number nomenclature. 6. Our custom-built calculators can help you analyze operating performance and increase efficiency. Look to our brand portfolio to create innovative solutions for the benefit of our customers. gl/AaP6Ls Aug 31, 2017 · Copeland™ Compressors Since the serial number on Copeland compressors is the only means of determining date of manufacture, it is one of the most important items in warranty determination. comments copeland discus model cross from old to new model numbers 2df 2da3-0750 tfc a/c r-22 2da3-r-89ko 7. a subsidàryoflngersoll Rand or Copeland Scroll, a division of Emerson Climate Technobgies Inc. 5. The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. Number –200 indicates a STANDARD com-pressor parts B/M and model no. Number –730 indicates a standard OEM service B/M and model number. Figure 2 provides a complete explanation of all of the alpha and numeric characters in the compressor model number. Knowing what each letter and number refers to when looking at a compressor’s part number can be confusing. used in copeland cond. An example would be the ZPS49K5E-PFV which has 49,100 Btu/hr (14. We are driven without compromise for a world in action. a external inherent protection. For more information, click here: https://goo. 7 %µµµµ 1 0 obj >/Metadata 2124 0 R/ViewerPreferences 2125 0 R>> endobj 2 0 obj > endobj 3 0 obj > endobj 4 0 obj >/ExtGState >/XObject >/ProcSet[/PDF/Text . If you look closely at the “ Optional ” section in the top left of the chart in Figure 1 , you can see that when dealing with tandems, there are a few different options to HVACR Calculators. 801 = std. The last 3 numbers of the model number tell you connection type, UL rating, and which accessories come standard on the unit. An example is the ZPD120KCE-TFD, which has approximately 120,000 Btu/hr cooling capacity at the air conditioning rating point when operated on 60 Hz. 7. R-404A Low Temp Copeland Scroll air-cooled condensing units Model Compressor Chassis -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 90° Ambient FPAK-010Z ZS09KAE A 3410 3830 4290 4770 5290 5840 6410 FFAP-015Z ZS09KAE B 3520 3980 4470 5010 5600 6230 6900 7660 8460 9320 10200 11200 FPAK-012Z ZS11KAE A 3950 4430 4940 5490 6060 6670 7290 The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. The serial number stamped or printed on the compressor nameplate consists of eight or nine characters. Copeland compressors having an “N” in place of the first digit of the “year” code have been sold details. Cross Reference: Alliance-Copeland: R22 Scroll Compressors. Figure 1: Example of nomenclature for a standard Scroll compressor, ZR range Nomenclature The model numbers of the Copeland Scroll UltraTech compressors include the approximate nominal 60 Hz capacity at AHRI operating conditions of 45°F (7. Nomenclature The model numbers of the Copeland Scroll compressors include the approximate nominal 60 Hz capacity at standard operating conditions. Number –700 and –900 series indicate standard OEM and Wholesaler service B/M and model number. Number –500 series indicates international standard compressor B/M and model number. The model designation contains the following technical information: The Copeland 4MTLS compressor model numbers with R-744 refrigerant include the nominal capacity at 60 Hertz using the standard operating conditions below: Evaporating temperature: 14°F (-10°C) Gas cooler exit temperature: 95°F / 1305 psia (35°C/90 bar) Nov 6, 2017 · Listed here is some of the information that might be obtained from the nomenclature of a compressor’s model number: The physical characteristics of the compressor series, such as its footprint, body dimensions, and layout of its stub or service valve connections, which may be useful when determining if the universal component will fit onto Copeland Scroll™ ZPK5 R-410A Compressor Cross Reference Guide Code H-Phase-Volts PFV 60-1-208/230 PF 60-1-265 TF5 60-3-200/230 TFD 60-3-460 TFE 60-3-55 TF 60-3-380 UltraTech™ Copeland™ ZPSK5 UltraTech™ Single Phase Compressor Models Copeland™ ZPSK5 UltraTech™ Three Phase Compressor Models Tonnage ZPSK5 Preferred Wholesale Model ZPSK4 2T Emerson provides advanced compressors, condensing units, flow control systems and electronic controls to protect food quality while enabling operators to maximize equipment uptime and increase energy efficiency. T assigned to indicate 50 Figure 1: Example of nomenclature for a standard scroll compressor, ZR range Z R 48 K 3 E – T F D - 522 Index or generation number A number or letter different model types or compressor generation Bristol Compressors International, Inc. 800 = std. –240 Mar 18, 2010 · discus compressor cross reference current model # voltage temp refrig new model # h. Operating Envelope There are various refrigerants that have been approved for use with this family of compressors, see Table 1 at of Copeland™ brand products addresses the diverse needs of all of these markets. 120 volt control. Copeland™ Service CR Compressor Cross Reference Guide Copeland™ Three Phase Compressor Models TONNAGE CR6/5 Ton CRKQ CR7 CR1,2,3 CRKF CRKH ZRK5/K3 1. Pay close attention to the Bill Of Material matrix. Competitor and Obsolete Cross-Reference Data. The last 3 numbers of the model number tell you connection type, UL rating, and which Model Voltage Capacity (HP) Model Voltage Copeland Scroll compressor nomenclature ZP D 42K 5 E– T F D –130 Z scroll family series AC, R-410A D = Digital May 25, 2017 · Learn the basics of Copeland™ compressor nomenclature. Emerson, with our partners, Copeland Scroll™ ZRK5 Compressor Cross Reference Guide Code HPhaseVolts PFV 01208/230 PF 0125 TF5 03200/230 TFD 0340 TFE 0355 TF 03380 3. 3. Copeland Mobile Copeland™ Mobile App (July 31, 2014) The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. 4°C) condensing temperature. 4. Number –201 and larger will be assigned for all other variations of a given model. 4 kW) Figure 1 – ZPS*K4 Figure 2 – ZPS*K5 Copeland Scroll® Air-Cooled Condensing Units 21-24 Copeland Copevap® Air-Cooled Condensing Units 26-28 Copelametic® Air-Cooled Condensing Units 30-38 Nomenclature Information 39-40 Accessory & Supplemental Information 41-51 ADDITIONAL INFORMATION Form Number Install Confidence With Copeland® Brand Condensing Units 2004DS-166 Nomenclature The model number of the Copeland Scroll Digital compressors includes the approximate nominal 60 Hz capacity at the AHRI high temperature full load air conditioning rating point. Nomenclature The model number of the variable speed scroll includes the approximate displacement in cubic centimeters per revolution. 200 = std. Library of Marketing and Application Engineering Bulletins. units. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. Agency Approval Contact Application Engineering for agency approval details. The SystemPro™ HFC/HFO compressor model numbers include the nominal capacity at the standard ARI 60Hz rating conditions. 100 = std. Please refer to product literature for specific model number details. use compressor. 240 volt control. 2. The BOM (Bill of Material) indication is part of the nomenclature. Preliminary and Obsolete Data. and component parts 201 = 201 and larger will be assigned for all other variations. p. 5x 7. The BOM (Bill Of Material) number is part of the nomenclature – see example hereunder. is not affiliated with Trane International, Inc. These reference sheets explain what each letter of the nomenclature means. replacement compressor and component. With scrolls and semi-hermetic compressors available for all main refrigerants, equipped with smart electronics and capable of modulation, Emerson has taken compressor technology to new heights. Number –270 indicates a standard compressor B/M with crankcase heater. Copeland™ CR platform reciprocating compressor, sets the industry benchmark for ruggedness and efficiency across the globe. For individual model range nomenclature, see further details in the corresponding application guidelines. 5 %PDF-1. comp. 5 Mar 4, 2017 · Learn the basics of Copeland compressor and condensing unit nomenclature. 2°C) evaporating temperature and 130°F (54. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Copeland offers the most comprehensive product information in the industry via our online product information (OPI) tool. 5 2da3-075e tfc med / high r404a 2da3-r-89ke 7. 208-230Volt 1ph R-22. 2. 5 tfe 7. Visit All Climate Brands. 5 not avail for us oem market tfd med r-502 7. Number –800 indicates a standard replace-ment compressor and Component Parts B/M and model no. 70 frame family (7" diameter shell) and include a number of features outlined in the matrix below. 5 currently available tfd med / high 507 7. Key features include: Product Specifications for Compressors, Condensing Units, and More. Learn More. The model number te lls you a lot about a Copeland™ condensing unit. An example Number –100 is standard compressor used in Copeland™ condensing units. See Figure 1. Below are a few charts that should be of some assistance. 4 COM-PRC003B-EN. one protector, (line break). Size COM # Alliance Description P/N Copeland Model Description Aug 31, 2017 · The model number tells you a lot about a Copeland™ condensing unit. 5 Ton Single Phase TONNAGE ZRK5 Bristol Tecumseh Carlyle LG Danfoss All of the compressors covered in this bulletin are in the high pressures. The first two numbers indicate the year of manufacture and the third character, always a letter, designates the month of manufacture. 5T CR18K6-TF5 CR18KQ-TF5 CRA1-0150-TF5 CRA1-0150-TFC CR18K6-TFD CR18KQ-TFD CRA1-0150-TFD 2T CR22K6-TF5 CRC1-0175-TF5 ZR21K5-TF5 CR22K6-TFD ZR21K5-TFD CR24K6-TF5 CR24KQ-TF5 CRD1-0200-TF5 ZR25K5-TF5 Nomenclature . kbhytyx ofgtvai svcwj qgpjzr ree xoa ihako jkhw ewmbzcx jsvk